Vapour cloud development in over-filling incidents

  • Main
  • Vapour cloud development in...

Vapour cloud development in over-filling incidents

Steel Construction Institute (Great Britain). Fire and Blast Information Group., Steel Construction Institute (Great Britain)
Koliko vam se sviđa ova knjiga?
Kakav je kvalitet fajla?
Preuzmite knjigu radi procene kvaliteta
Kakav je kvalitet preuzetih fajlova?
Describes an assessment method for calculating the rate at which the volume of a vapour cloud increases during an overfilling incident. The assessment also gives the concentration of hydrocarbons in the cloud and provides some guidance on the extent of cloud spread in relatively flat sites with the kind of obstructions that would be normal in and around a fuel depot tank farm. This Technical Note allows vapour cloud assessment for an overfill of a range of fuels and solvents that are commonly stored in large volumes. Substance/mixture specific equilibrium thermodynamic analysis of air/liquid mixtures in humid atmospheres has been conducted and an empirical correlation and constants are provided that will allow the vapour concentration at the foot of the overfill cascade to be predicted. Whilst the HSE VCA method was developed for vapour cloud development resulting from overfills in calm conditions, this Technical Note gives some preliminary guidance on extending the assessment to low (non-zero) wind speeds and to calculating the rate at which a cloud may accumulate in the case of spray releases (e.g. flange failure or pipe rupture).
Abstract: Describes an assessment method for calculating the rate at which the volume of a vapour cloud increases during an overfilling incident. The assessment also gives the concentration of hydrocarbons in the cloud and provides some guidance on the extent of cloud spread in relatively flat sites with the kind of obstructions that would be normal in and around a fuel depot tank farm. This Technical Note allows vapour cloud assessment for an overfill of a range of fuels and solvents that are commonly stored in large volumes. Substance/mixture specific equilibrium thermodynamic analysis of air/liquid mixtures in humid atmospheres has been conducted and an empirical correlation and constants are provided that will allow the vapour concentration at the foot of the overfill cascade to be predicted. Whilst the HSE VCA method was developed for vapour cloud development resulting from overfills in calm conditions, this Technical Note gives some preliminary guidance on extending the assessment to low (non-zero) wind speeds and to calculating the rate at which a cloud may accumulate in the case of spray releases (e.g. flange failure or pipe rupture)
Godina:
2013
Izdavač:
Steel Construction Institute
Jezik:
english
Strane:
34
ISBN 10:
1621987000
ISBN 13:
9781621987000
Serije:
Steel Construction Institute (Great Britain).; Fire and Blast Information Group.; FABIG technical note 12
Fajl:
PDF, 2.54 MB
IPFS:
CID , CID Blake2b
english, 2013
Preuzeti (pdf, 2.54 MB)
Konvertovanje u je u toku
Konvertovanje u nije uspešno

Najčešći pojmovi